SM Single Mode G652D GYTA 24-vezels Direct Burial Outdoor Fiber Optical Cable
Technische gegevens van de GYTA-kabel
| Kabeltype | Vezelgehalte | Buizen | Vulstoffen | Kabeldiameter mm | Kabelgewicht kg/km | Treksterkte Lange/Korte termijn N | Drukweerstand Lange/Korte termijn N/100mm | Buigradius Statisch mm |
| GYTA-2~12 | 8~12 | 1 | 4 | 9.0 | 100 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-14~18 | 14~18 | 3 | 2 | 9.0 | 100 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-20~24 | 20~24 | 4 | 1 | 9.5 | 110 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-26~36 | 26~36 | 4 | 1 | 9.5 | 120 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-38~48 | 38~48 | 4 | 1 | 10.0 | 140 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-50~60 | 50~60 | 5 | 0 | 10.8 | 150 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-62~72 | 62~72 | 6 | 0 | 11.9 | 170 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-74~84 | 74~84 | 7 | 1 | 12.5 | 180 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-86~96 | 86~96 | 8 | 0 | 13.6 | 210 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-98~108 | 98~108 | 9 | 1 | 14.5 | 230 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-110~120 | 110~120 | 10 | 0 | 14.8 | 240 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTS-122~144 | 122~132 | 11 | 1 | 15.4 | 260 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-146~216 | 146~216 | 12 | 0 | 19.8 | 395 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-218~288 | 218~288 | 12 | 0 | 20.8 | 470 | 1000/3000 | 1000/3000 | 10D/20D |
Vezelkenmerken:
| Vezelstijl | Eenheid | SM G652D | SM G657A | MM 50/125 | MM 62,5/125 | MM OM3-300 | MM OM4-550 | |
| Voorwaarde | nm | 1310/1550 | 1310/625 | 850/1300 | 850/1300 | 850/1300 | 850/1300 | |
| Verzwakking | dB/km | ≤0,34/0,22 | ≤.035/0.21 | ≤3,0/1,0 | ≤3,0/1,0 | ≤3,0/1,0 | ≤3,5/2,2 | |
| Dispersie | 1550 nm | Ps/(nm*km) | ≤18 | ≤18 | ---- | ---- | ---- | ---- |
| 1625 nm | Ps/(nm*km) | ≤22 | ≤22 | ---- | ---- | ---- | ---- | |
| Bandbreedte | 850 nm | MHZ.KM | ---- | ≥400 | ≥160 | |||
| 1300 nm | MHZ.KM | ---- | ≥800 | ≥500 | ||||
| Nuldispersiegolflengte | nm | ≥1302 ≤1322 | ≥1302 ≤1322 | ---- | ---- | ≥ 1295, ≤1320 | ≥ 1295, ≤1340 | |
| Nulspreidingshelling | nm | ≤0,091 | ≤0,090 | ---- | ---- | ---- | ---- | |
| PMD Maximale individuele vezel | ≤0,2 | ≤0,2 | ---- | ---- | ≤0,11 | |||
| PMD-ontwerp Linkwaarde | Ps(nm2*km) | ≤0,08 | ≤0,1 | ---- | ---- | ---- | ---- | |
| Vezelafsnijgolflengte λc | nm | ≥1180 ≤1330 | ≥1180 ≤1330 | ---- | ---- | ---- | ---- | |
| Kabeldoorsnijding golflengte λcc | nm | ≤1260 | ≤1260 | ---- | ---- | ---- | ---- | |
| MFD | 1310 nm | um | 9,2 ± 0,4 | 9,0±0,4 | ---- | ---- | ---- | ---- |
| 1550 nm | um | 10,4 ± 0,8 | 10,1 ± 0,5 | ---- | ---- | ---- | ---- | |
| Numeriek Diafragma (NA) | ---- | ---- | 0,200 ± 0,015 | 0,275± 0,015 | 0,200± 0,015 | 0,200± 0,015 | ||
| Stap (gemiddelde van bidirectioneel) meting) | dB | ≤0,05 | ≤0,05 | ≤0,10 | ≤0,10 | ≤0,10 | ≤0,10 | |
| Onregelmatigheden in vezellengte en punt | dB | ≤0,05 | ≤0,05 | ≤0,10 | ≤0,10 | ≤0,10 | ≤0,10 | |
| Verschil-terugverstrooiing coëfficiënt | dB/km | ≤0,03 | ≤0,03 | ≤0,08 | ≤0,10 | ≤0,08 | ≤0,08 | |
| Uniformiteit van de demping | dB/km | ≤0,01 | ≤0,01 | |||||
| Kerndiameter | um | 9 | 9 | 50±1,0 | 62,5±2,5 | 50±1,0 | 50±1,0 | |
| Bekledingsdiameter | um | 125,0±0,1 | 125,0±0,1 | 125,0±0,1 | 125,0±0,1 | 125,0±0,1 | 125,0±0,1 | |
| niet-cirkelvormige gevelbekleding | % | ≤1,0 | ≤1,0 | ≤1,0 | ≤1,0 | ≤1,0 | ≤1,0 | |
| Diameter van de coating | um | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | |
| Coating/vink concentrische fout | um | ≤12,0 | ≤12,0 | ≤12,0 | ≤12,0 | ≤12,0 | ≤12,0 | |
| Niet-circulariteit van de coating | % | ≤6,0 | ≤6,0 | ≤6,0 | ≤6,0 | ≤6,0 | ≤6,0 | |
| Concentriciteitsfout van de kern/bekleding | um | ≤0,6 | ≤0,6 | ≤1,5 | ≤1,5 | ≤1,5 | ≤1,5 | |
| Krul (straal) | um | ≤4 | ≤4 | ---- | ---- | ---- | ---- | |
Vezelkleur:
| 1 | 2 | 3 | 4 | 5 | 6 |
| Blauw | Oranje | Groente | Bruin | Grijs | Wit |
| 7 | 8 | 9 | 10 | 11 | 12 |
| Rood | Zwart | Geel | Violet | Roze | Aqua |
Beschrijving van de GYTA-kabel
De vezels, met een diameter van 250 μm, zijn geplaatst in een losse buis van een kunststof met een hoge elasticiteitsmodulus.
+ De buizen zijn gevuld met een waterbestendige vulmassa.
+ Een stalen draad, soms omhuld met polyethyleen (PE) voor kabels met een hoog vezelgehalte, bevindt zich in het midden van de kern als metalen trekontlastingselement.
+ Buizen (en vulmaterialen) worden rond het trekontlastingselement gewikkeld tot een compacte en cirkelvormige kabelkern.
+ EenAluminium-polyethyleenlaminaat (APL)Het wordt aangebracht rond de kabelkern, die gevuld is met een vulmiddel om deze te beschermen tegen waterindringing.
+ De kabel is afgewerkt met een PE-mantel.
Bouw:
Kenmerken van GYTA-kabels:
+ Goede mechanische en temperatuurprestaties
+ Sterke, losse buis die bestand is tegen hydrolyse
+ Speciaal vulmiddel voor tubes zorgt voor een cruciale bescherming van de vezels.
+ De speciaal ontworpen compacte structuur voorkomt dat losse buizen krimpen.
+ PE-mantel beschermt de kabel tegen ultraviolette straling
De volgende maatregelen worden genomen om de waterdichtheid van de kabel te garanderen:
+ Staaldraad gebruikt als centraal verstevigingselement
+ Vulmiddel voor losse tubes
+ 100% vulling van de kabelkern
+ 100% getest voor verzending.
+ Kabelhaspellengte: 1 km, 2 km, 3 km, 5 km
GYTA-kabeltoepassing:
+ Geschikt voor distributie in de buitenlucht.
+ Geschikt voor het leggen van pijpleidingen, directe begraving en ondergrondse methoden.
+ Communicatie via langeafstands- en lokale netwerken.
Verpakking: